Welding table (set value)
Process
1.0 mm
Material
Wire
Gas
S
U0
(m/min)
(V)
Fe
0.8
CO
2.5
19.0
2
Fe
1.0
CO
2.0
18.0
2
Fe
1.2
CO
1.0
18.0
2
Fe
0.8
ArCO
3.0
16.0
2
Fe
1.0
ArCO
2.0
15.0
2
Fe
1.2
ArCO
1.5
16.5
2
Fe
1.6
ArCO
2
CrNi
1.0
ArCO
3.0
15.0
2
CrNi
1.2
ArCO
2.0
15.0
2
AI
1.0
Ar
4.0
14.5
AI
1.2
Ar
3.5
13.0
Process
4.0 mm
Material
Wire
Gas
S
U0
(m/min)
(V)
Fe
0.8
CO
13.0
29.0
2
Fe
1.0
CO
6.0
22.5
2
Fe
1.2
CO
4.5
23.0
2
Fe
0.8
ArCO
14.0
26.0
2
Fe
1.0
ArCO
8.0
20.0
2
Fe
1.2
ArCO
5.5
20.5
2
Fe
1.6
ArCO
3.0
19.5
2
FeFlux
1.2
ArCO
6.0
21.0
2
CrNi
1.0
ArCO
9.0
25.0
2
CrNi
1.2
ArCO
8.0
24.0
2
AI
1.0
Ar
11.0
22.0
AI
1.2
Ar
10.0
18.0
1.5 mm
2.0 mm
3.0 mm
S
U0
S
U0
S
(m/min)
(V)
(m/min)
(V)
(m/min)
4.5
19.5
7.0
21.0
11.0
2.5
19.0
3.0
20.0
4.5
2.0
20.0
2.5
21.0
3.5
6.0
18.0
7.5
19.5
11.0
3.0
16.0
4.0
17.0
6.0
2.5
17.5
3.5
18.0
4.5
1.0
17.0
2.0
18.0
2.5
4.0
16.0
6.0
17.0
8.5
3.0
16.0
3.5
16.5
6.0
6.0
15.0
7.5
16.0
9.0
5.0
15.0
8.0
16.0
9.0
6.0 mm
10.0 mm
S
U0
S
U0
(m/min)
(V)
(m/min)
(V)
18.0
30.0
24.0
37.0
9.0
24.5
14.0
32.0
7.5
28.5
11.0
36.0
18.0
31.0
24.0
33.0
11.5
26.5
16.0
30.0
8.0
29.0
10.0
32.0
4.0
22.0
5.5
29.0
8.0
25.0
11.0
28.0
10.0
27.0
10.0
24.0
12.0
31.0
13.0
25.0
15.0
27.0
13.0
23.0
15.0
26.0
Table 1
Setting the welding process
Press and hold (11A) to open for setting the welding process. Choose parameter by turning (10).
Set the chosen value by turning (11). To close this function, press (11A) briefly.
Press (12) briefly to turn display of Fxx (F = function) parameter names on/off.
U0
(V)
27.0
MIG/MAG parameters
21.0
22.0
A
20.0
19.0
20.5
18.5
20.0
m/min
18.0
19.0
t1
S
17.0
GS.F / F22 (gas flow) 0,5-27 l/min (only machines with IGC) (optional equipment)
MMA (electrode) parameters
When the MMA welding program is chosen, the operator is
allowed access to the following parameters only
A
t
Set welding
Figure 1
OMEGA
Actual welding current (A)
t
t2
S
S
HS.A / F11 Hotstart
HS.t / F12 Hotstart time
Arc / F13
Arc force
Short circuit
current (A)
t
QUICKGUIDE
YARD BASIC
3
Pr.G / F31
Pre-gas
(0.2 sec.)
S.St / F32
Soft start
(1.0 m/min.)
bb.t / F37
Burn-Back
(5 (0-30))
Po.G / F38 Post-gas
(3.0 sec.)
SP.t / F39
Spot time
(0.0 sec.)
t
(25%)
(0,5 sek.)
(25%)
UK 50113783 A