1.
Connect neutral bond wire
and neutral wire
E
D
Remove center terminal block screw. Remove neutral bond
wire from external ground conductor screw. Connect neutral
bond wire and the neutral wire (white or center wire) of
power supply cord under center terminal block screw.
Tighten screw.
A. Center terminal block screw
B. Neutral bond wire
C. External ground conductor screw – Dotted
line shows position of NEUTRAL bond
wire before being moved to center terminal
block screw.
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL Listed strain relief
2.
Connect ground wire
A
F
Connect ground wire (green or bare) of power supply cord
to external ground conductor screw. Tighten screw.
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. Neutral bond wire
D. External ground conductor screw
E. Ground wire (green or bare) of power
supply cord
F. 3/4" (19 mm) UL Listed strain relief
Connect the other wires to outer terminal block screws. Tighten
screws. Tighten strain relief screws. Insert tab of terminal block
cover into slot of dryer rear panel. Secure cover with hold-down
screw. Now go to "Venting Requirements."
A
B
C
B
C
E
D
3-Wire Power Supply Cord Connection
IMPORTANT: Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
3-wire receptacle
(NEMA type 10-30 R)
Spade terminals
with upturned ends
1.
Connect neutral wire
A
Loosen or remove center terminal block screw. Connect neutral
wire (white or center wire) of power supply cord to the center
terminal screw of the terminal block. Tighten screw.
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. Neutral bond wire
D. External ground conductor screw
E. 3/4" (19 mm) UL Listed strain relief
Connect the other wires to outer terminal block screws. Tighten
screws. Tighten strain relief screws. Insert tab of terminal block
cover into slot of dryer rear panel. Secure cover with hold-down
screw. Now go to "Venting Requirements."
3 prong plug
Ring terminals
B
C
E
D
23