Determine vent length and elbows needed for best
drying performance:
Use following Vent System Chart to determine type of vent
Ƀ
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in Vent
System Chart. Exhaust systems longer than those specified
will:
Shorten life of dryer.
Ƀ
Reduce performance, resulting in longer drying times
Ƀ
and increased energy usage.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.
Vent System Chart, 27" (69 cm) Models
Number of 90°
turns or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
Vent System Chart, 24" (61 cm) Models
Number of 90°
turns or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
NOTE: Side exhaust installations (24" (69 cm) models only)
have a 90º turn inside the dryer. To determine maximum
exhaust length, add one 90º turn to the chart.
Vent System Chart,
27" (69 cm) Long Vent Models
WETLV27H and WGTLV27H (U.S. Only)
Number of 90°
turns or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
5
Rigid metal
Type
Angled
of vent
hoods
35 ft (10.7 m)
27 ft (8.2 m)
19 ft (5.8 m)
Type
Angled
of vent
hoods
36 ft (11.0 m)
26 ft (7.9 m)
16 ft (4.9 m)
Type
Angled
of vent
hoods
125 ft (38.1 m)
115 ft (35.1 m)
105 ft (32.0 m)
95 ft (29.0 m)
85 ft (25.9 m)
75 ft (22.9 m)

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fit inside the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
12" minimum
(305 mm)
12" minimum
(305 mm)