Checking the tightness of the connection
GB
! When the installation process is complete, check the pipe
fittings for leaks using a soapy solution. Never use a flame.
Adapting to different types of gas
To adapt the hob to a different type of gas other than default
type (indicated on the rating plate at the base of the hob or
on the packaging), the burner nozzles should be replaced
as follows:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner, and
replace them with nozzles for the new type of gas (see
table 1 "Burner and nozzle characteristics").
3. Reassemble the parts following the above procedure in
the reverse order.
4. Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used.
Sticker are available from any of our Service Centres.
Replacing the Mini DUAL burner nozzles*
1. Remove the hob grids and slide the burners off their
seats. The burner consists of two separate parts.
2. Loosen the 3 screws and remove the burner.
3. Loosen the 2 screws (see figure).
A
B
5. Replace all the components by following the above
instructions in reverse.
• Adjusting the burners' primary air
Does not require adjusting.
*
Only available on certain models.
24
All manuals and user guides at all-guides.com
In the case of the Mini WOK*, use
a spanner with a 7 mm opening to
unscrew the nozzle (see figure).
4. Unscrew nozzle "A" using a 7
mm socket spanner. Use a
spanner with a 7 mm opening to
unscrew nozzle "B" (see figure).
Replace the nozzles with models
which are suitable for use with the
new type of gas (see table 1).
• Setting the burners to minimum
1. Turn the tap to the low flame position;
2. Remove the knob and adjust the adjustment screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
3. Having adjusted the flame to the required low setting,
while the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the flame does not go out.
4. Some appliances have a safety device (thermocouple)
fitted. If the device fails to work when the burners are set
to the low flame setting, increase this low flame setting
using the adjusting screw.
5. Once the adjustment has been made, replace the seals on
the by-passes using sealing wax or a similar substance.
! If the appliance is connected to liquid gas, the regulation
screw must be fastened as tightly as possible.
! Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used. Stickers
are available from any of our Service Centres.
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be fitted to the inlet pipe (in order to comply
with current national regulations).
DATA PLATE
Electrical
see data plate
connections
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.