MAINTENANCE INSTRUCTIONS
Emptying & Cleaning the Cyclonic
Chamber
Periodically the cyclonic chamber will
need to be emptied and cleaned. This
does not have to be done every time the
dust cup is emptied but it is recommended
that you empty the cyclonic chamber
every three (3) months depending on use
or prior to the dust in the cyclonic
chamber reaching the "MAX" fill line. If dirt
level is not visible, clean every three
months.
To empty the cyclonic chamber:
1. Hold the cyclonic chamber from the
handle over a garbage can and
press the cyclonic
chamber bottom
door release button
to empty the dust.
(Fig. 29) You can
gently tap clean it
Cyclonic Chamber
Bottom Door
against the side
Release Button
of the garbage
can to make sure
that all the dust
Fig. 29
has been emptied from the cyclonic
chamber.
2. After emptying the cyclonic chamber,
replace it onto the dust cup and place
the dust cup assembly into the
vacuum.
Filter Indicator Light
When the filter indicator light flashes, it
means that the dust cup is full, the filters
need cleaning or there is a blockage in the
air paths. You must empty the dust from
the dust cup, clean the debris screen, clean
the filters and check the unit for any
blockages. (Fig. 30)
Filter
Indicator
Light
Fig. 30
Note
: Occasionally the filter indicator
light will flash momentarily if the air path
is blocked when using the above floor
tools. This is normal.
All manuals and user guides at all-guides.com
Cleaning Pre-Motor Filters
Under normal use, the 2 filters in the
filter housing should be cleaned every
three (3) to five (5) months for optimal
performance of your vacuum. The filter
indicator light will flash when the filters
need cleaning.
To remove the filter housing:
1. Hold the filter housing by the air
inlet and turn counter clockwise to
unlock. (Fig. 31)
Fig. 31
2. Turn the filter housing upside down
and turn the filter housing base
counter clockwise to open. Remove
the filter housing base. (Fig. 32)
Fig. 32
3. Inside the filter housing are two filters.
Filter 1 is a foam filter and Filter 2 is a
felt filter. Both are washable and
reusable for the lifetime of your
vacuum (under normal household
use). (Fig. 33, Fig. 34)
Foam Filter
Felt Filter
Fig. 33
Fig. 34
9
MAINTENANCE INSTRUCTIONS
4. Rinse the filters in lukewarm water
until the water runs clear. Squeeze
and let the filters air dry for 24 hours
before re-installing into the filter
housing. Do not use a washing
machine to clean the filters. Do not
use a hair dryer to dry them. Air dry
only. You can also rinse the filter
housing if you wish. Never operate
the vacuum without ALL the filters in
place. (Fig. 35)
Note:
To continue using your vacuum
while the pre-motor filters are drying, you
can replace them with the extra set of pre-
motor filters that are included.
Foam Filter
Felt Filter
Fig. 35
5. When the filters are
Housing
dry, replace them
into the dry filter
Felt
housing. Insert the
Filter
foam filter (filter 1)
first and then place
Foam
Filter
the felt filter (filter 2)
over the foam filter.
Housing
6. Replace the filter
housing base on to
the filter housing.
Fig. 36
(Fig. 36) Align the
arrows on the filter housing with the
arrows on the filter housing base and
turn clockwise to lock in place.
(Fig. 37)
ALIGN HERE TO CLOSE
ALIGN HERE TO CLOSE
Fig. 37
Removing & Cleaning the Lifetime
Washable HEPA Filter
Under normal use, the HEPA filter
should be tapped cleaned and rinsed
once every three (3) years or as needed
depending on usage. This is located
underneath the filter housing.
To remove the HEPA filter:
1. Remove the filter housing.
2. Hold the HEPA filter by the center
opening and lift it up. (Fig. 38)
Fig. 38
3. Vigorously tap clean the HEPA
filter on a hard surface to remove
any residual dust that might be on
the HEPA filter. (Fig. 39)
Filter
Base
Fig. 39
Filter
4. You can wash the HEPA filter by
running it under the tap allowing the
water to run on the dirty side.
(Fig. 40) Always allow 24 hours for
air drying before replacing into the
vacuum.
Fig. 40
5. Replace the HEPA filter back into the
vacuum after it has air dried for 24
hours.
Please Note
: The white material in the
HEPA filter will discolor over time - This
is NORMAL and will NOT affect the
performance of the filter.