Installation Instructions; Installation Considerations - Thermador VCIN36GWS Instrucciones De Instalación

Ocultar thumbs Ver también para VCIN36GWS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions

Installation considerations

Clearances and requirements
The custom insert unit is designed for installation inside a
custom-built hood assembly. It is for ducting to the
outside. It cannot be used in conjunction with a
recirculation unit.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
inches (millimeters)
7/ 7/
7/
7
7
7
16
16
16"
"
(189)
(189)
(189)
11/ 16 "
12
12
12
(326)
(326)
(326)
* 30" (762) –
40" (1,016)
* Follow cooking appliance manufacturer's
recommendations.
Hood width
The hood width should be no less than the width of
the cooking surface. For proper performance, the
housing must cover the entire cooking surface.
For proper performance, the hood must be centered
horizontally above the cooking surface. Where space
is not restricted, a wider hood can be used to increase
capture area.
6
Electrical
Zone
Distance from cooking surface
Hood installation height above a cooktop, rangetop
or range can vary.
The installation height ranges from a minimum height
of 30'' (762 mm) to a suggested maximum height of
40'' (1,016 mm). However, it is necessary to follow the
cooking appliance manufacturer's installation
instructions for proper hood height.
NOTICE: The hood could incur some damage from heat if
a Thermador Professional
operated with multiple burners at high settings under a
hood that is installed at minimum clearances while the
hood is turned off.
Unit weight
This vent hood is heavy. Adequate structure and
support must be provided in all types of installations.
When calculating the load for the housing support
system, be sure to consider the weight of the
ventilation unit.
Description
VCIN36WS
VCIN42WS
VCIN48WS
VCIN54WS
VCIN60WS
Integral blower VTN2FZ
Integral blower VTN1DZ
NOTICE:
The supplied weights address only the ventilation unit or
blower. Installer must account for weight of any materials
of construction when calculating the total dead weight
load of installation, including but not limited to: wall, tile,
mortar, plaster, brick, finishes, partitions, and other
similarly incorporated architectural and structural items.
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
Support structure
Wall framing should be, at minimum, made of 2"x 4"
lumber. Proper structural support is required to
accommodate the weight of the hood.
Venting
The hood requires the ducting to be vented to the
exterior of the building.
®
series range or rangetop is
Weight
53 lb (24 kg)
63 lb (29 kg)
69 lb (31 kg)
79 lb (36 kg)
85 lb (39 kg)
19 lbs. (8.6 kg)
8 lbs. (3.6 kg)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vcin42gwsVcin48gwsVcin54gwsVcin60gws

Tabla de contenido