enGliSH
electrical SpecificationS
capacitance (auto-ranGinG)
range
40.00nF
400.0nF
4.000μF
40.00μF
400.0μF
4000μF
Maximum input: 600V DC or 600V AC RMS
frequency (auto-ranGinG)
9.999Hz
99.99Hz
999.9Hz
9.999kHz
99.99kHz
500.0kHz
Sensitivity: > 8V RMS
Maximum input: 600V DC or 600V AC RMS

Duty cycle

1% to 99.9%
pulse width: 0.1 – 100ms
frequency width: 5Hz to 10kHz
Sensitivity: >8V RMS
Maximum input: 600V DC or 600V AC RMS
teMperature
0° to 1500°F
-18° to 816°C
4
MM700-1390112ART.indd 4
Dwg Name: MM700-1390112ART
Dwg No: 1390112
ECO No: 20617
Pkg Dwg Ref: 1290186
Color Reference: N/A
resolution
accuracy
10pF
±(5.0% + 35 digits)
0.1nF
1nF
±(3.0% + 5 digits)
10nF
100nF
1μF
±(5.0% + 5 digits)
0.001Hz
0.01Hz
0.1Hz
±(1.0% + 5 digits)
1Hz
10Hz
100Hz
0.1%
±(1.2% + 2 digits)
0.1°F / 1°F
±(2.0% + 9°F)
0.1°C / 1°C
±(2.0% + 5°C)
Rev: E
otHer MeaSureMent applicationS
Maximum input: 100V RMS in Voltage s
• Diode test: 1.5 mA max, open circui
• continuity check: Audible signal whe
• low impedence (low Z): Input impe
• auto power off: After ~30 minutes of
• Sampling frequency: 3 samples per
• Bar Graph: 41 segment, 10-15 samp
• overload: "OL" indicated on display, 1
settings, 600V RMS in all
• polarity: "-" on display indicates nega
• Display: 3 ¾ digit, 4000 Count LCD,
to ensure safe operation and service o
instructions. failure to observe these w
severe injury or death.
• Before each use verify meter opera
voltage or current.
• Never use the meter on a circuit w
category based rating of this mete
• Do not use the meter during electric
• Do not use the meter or test leads i
• Use only with CAT IV rated test lead
• Ensure meter leads are fully seated
from the metal probe contacts whe
• Do not open the meter to replace b
are connected.
• Use caution when working with vo
or 60V DC. Such voltages pose a s
• To avoid false readings that can lea
replace batteries when a low batter
• Do not attempt to measure resista
circuit.
• Always adhere to local and national
protective equipment to prevent sho
where hazardous live conductors ar
• Meter is IP42 dust & water resistan
with water, thoroughly dry meter an
subsequent use.
9/21/2015 2:44:46 PM
electrical Specif
600V DC or 600V AC R
max test current 0
Max input