Emergency stop / light curtain and RESET connections
Category 1 - level C
RESET
Safety-related characteristic data
PL in accordance with EN ISO 13849-1:2015
Category in accordance with EN 13849-1:2015
PFH in accordance with EN ISO 13849-1:2015 (test every year)
B10d
DC
MTTFd [hours] in accordance with EN ISO 13849-1:2015
TM in accordance with EN ISO 13849-1:2015
Category 3 - level D
RESET
Safety-related characteristic data
PL in accordance with EN ISO 13849-1:2015
Category in accordance with EN 13849-1:2015
PFH in accordance with EN ISO 13849-1:2015 (test every year)
B10d
DC
MTTFd [hours] in accordance with EN ISO 13849-1:2015
TM in accordance with EN ISO 13849-1:2015
06/2020
4
3
5
6
2
1
4
3
5
6
2
1
EMERGENCY
STOP
EMERGENCY
STOP
Add a safety
relay between
the controller
and the
emergency
stop
19 / 144
6159932290_13
1 brown
2 white
3 blue
4 black
5 grey
6 pink
Value for one
Value for ten
controller
controllers
PL c
Cat. 1
1.11E-07
1.80E-07
20.000.000
45%
HIGH – 93 years
20 years
1 brown
2 white
3 blue
4 black
5 grey
6 pink
Value for one
Value for ten
controller
controllers
PL d
Cat. 3
8.57E-09
7.73 E-08
20.000.000
99%
HIGH – 93 years
20 years