Safety Instructions And Precautions; Double Insulation; Extension Cords; Electrical Connection - A-iPower PWE1801 Manual Del Propietario E Instrucciones De Operación

Lavadora a presión eléctrica 1800 psi, 1.1 gpm
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SAFETY
Safety Instructions and Precautions specifically for electricity and electrical
components in this product:

DOUBLE INSULATION

Double insulation is a safety system within
electric power tools, which eliminates the
need for the usual three-wire grounded
power cord. All exposed metal parts
are isolated from the internal motor
components with protecting insulation.
Double insulated products do not need to
be grounded.
WARNING: Electrical Shock
The double insulated system
is intended to protect the user
from shock resulting from a break in the
product's internal insulation. Observe
all normal safety precautions to avoid
electrical shock.
NOTE: Servicing of a product with double
insulation requires extreme care and
knowledge of the system and should be
technician. For service, we suggest
you return the product to your nearest
authorized service center for repair. Only
use original factory replacement parts when
servicing.

ELECTRICAL CONNECTION

This product has a precision-built electric
motor. It should be connected to a power
supply that is nominal 120V/60Hz AC
(typical U.S. household circuit).
Do not operate this product on direct
current (DC). A substantial voltage drop will
cause a loss of power and the motor will
overheat. If the product does not operate
when plugged into an outlet, double-check
the power supply.
FOR TECHNICAL QUESTIONS, PLEASE CALL 1-855-888-3598

EXTENSION CORDS

When using a power tool at a considerable
distance from a power source, be sure to
use an extension cord that has the capacity
to handle the current the product will draw.
An undersized cord will cause a drop in line
voltage, possibly resulting in overheating,
loss of power, and/or circuit breaker or
GFCI tripping. Use the chart to determine
the minimum wire size required in an
extension cord. Only round jacketed cords
listed by Underwriter's Laboratories (UL)
should be used.
When working outdoors with a product,
Use outdoor extension cords marked
SW-A, SOW-A, STW-A, STOW-A, SJW-A,
SJTW-A, or SJTOWA. These cords are
rated for outdoor use and reduce the risk
of electric shock. Inspect cord for loose or
exposed wires and cut or worn insulation.
It is possible to tie the extension cord and
power cord in a knot to prevent them from
becoming disconnected during use. Make
a knot, then connect the plug end of the
power cord into the receptacle end of the
extension cord. This method can also be
used to tie two extension cords together.
RECOMMENDED EXTENSION CORD
FOR USE WITH THIS PRODUCT:
Cord Length
25 ft.
50 ft
100 ft.
5
Wire Size (A.W.G.)
14
12
Not Recommended