Draining Tanks; Draining Recovery Tank; Draining Leftover Cleaning Sol; Machine Maintenance - Nobles Power Eagle 1016 Plus Manual Del Operador Y Piezas

Aspirador para moquetas con depósito incorporado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION

DRAINING TANKS

FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
ATTENTION: Use different buckets to fill and drain
machine to prevent solution system clogs.

DRAINING RECOVERY TANK

1. Turn off machine and unplug power cord.
2. Turn drain hose knob counterclockwise and pull
out plug to drain (Figure 8).
FIG. 8
3. After draining, replace drain hose knob securely.
DRAINING LEFTOVER CLEANING SOLUTION
1. Disconnect vacuum hose from recovery tank
dome and replace with .9m (3 ft) clean--out hose,
supplied with machine (Figure 9).
FIG. 9
2. Turn on Vacuum/Pump switch.
8
Find... Go To..
Home
3. Remove solution tank lid and vacuum out leftover
solution.
4. Drain recovery tank.

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow machines daily, weekly and monthly
maintenance procedures.
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.

DAILY MAINTENANCE

(Every 4 Hours of Operation)
1. Drain and rinse out recovery tank thoroughly
(Figure 10).
FIG. 10
2. Remove and clean float shut--off screen, located in
recovery tank (Figure 11).
FIG. 11
Power Eaglet 1016/1020 Plus (03- -06)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Power eagle 1020 plus1002564-10161002556-1020

Tabla de contenido