Repeat the procedure if you wish to restore the previous configuration.
Important note: when the Soft Start function is enabled, the control unit automatically disables the Starting Torque function, while if Soft Start
is disabled then Starting Torque is automatically enabled.
8.4.3. LED L3 - RELEASE STROKE (in opening phase):
The control unit is supplied by factory with the release stroke function disabled. This function consists of sending a closing command for
2 seconds before starting the opening stroke: in this way the release of the lock is facilitated to allow the correct execution of the opening
phase. Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE trimmer, repeat the above mention programming, by pressing
SELECT twice (obtaining fast flashing of LED L3 instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.4. LED L4 - SLAM LOCK: (in closing phase):
The control unit is supplied by factory with the Slam lock function disabled.
This function consists in adding, in the presence of a deceleration stage during closing, a stroke lasting 1 second at the maximum power or
at the power selected with the "FORCE" trimmer, in such a way as to ensure positive engagement of the gate lock, if installed. If you wish
to enable the Slam Lock function at maximum power, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• LED L4 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE trimmer, repeat the above mention
programming, by pressing SELECT twice
(obtaining fast flashing of LED L4 instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.5. LED L5 - ELECTRICK LOCK ACTIVATED BY DISABLED PED. BUTTON:
The control unit is factory set with the function for electric lock activation via the Pedestrian command disabled. The function
for electric lock activation with the Pedestrian command is used when, for example, the application consists of a sliding gate
with a pedestrian gate alongside. With this function enabled the sliding gate can be opened both using commands from
the P/P Pushbutton and the remotes, and via the PED commands from the pedestrian gate by activating the electric lock.
To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.4.6. LED L6 - FLASHING LIGHT / INDICATOR LIGHT / COURTESY LIGHT:
By activating this function it is possible to change the indicator light (it does not flash during the pause), while the flashing output becomes
a courtesy light. To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• LED L6 becomes steady on and programming will be completed.
If you wish to enable the second variation, repeat the operation described above, pressing the SELECT key twice (obtaining the fast
flashing of the LED L6 instead of once) and then press SET (the LED does not light up).
Repeat the procedure if you wish to restore the previous configuration.
Courtesy Light Operation: The 24 ~ 4W max. Courtesy Light output will switch on for 3 minutes whenever an opening command is
transmitted.
8.4.7. LED L7 - PRE-FLASH/FLASH IN PAUSE:
The control unit is supplied by the factory with the Pre-flashing and Flashing during Pause (3 sec. pre-flash before closing phase) both disabled.
Pre-flashing operation: The 24V flasher output will always be activated 3 seconds before the closing manoeuvre.
If you wish to enable the Preflashing function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• LED L7 becomes steady on and programming will be completed.
Flashing operation during the Pause: The 230 Vac and 24V flashing light output will remain active if the pause time is previously programmed.
If you wish to enable this function, repeat the operation described above, pressing the SELECT key twice (obtaining the fast flashing of the
L7 LED) and then press SET. The L7 LED will remain on steady.
Repeat the procedure if you wish to restore the previous configuration.
COMUNELLO ®Copyright 2021 - All rights reserved