Rectifying faults
If a fault (e.g. a filter damage) occurs, the vacuum
u
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Problem
The suction turbine will not switch on. – Check the mains cable, mains plug, fuse, socket and fill level sensors (35).
The suction turbine switches off.
The suction turbine will not switch on
again after the container has been
emptied.
The suction power is decreasing.
Dust is escaping when vacuuming
Automatic switch-off (wet vacuuming)
is not working.
The automatic filter cleaning function
is not working.
The automatic filter cleaning function
will not switch off.
The automatic filter cleaning function
will not switch on.
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
1 609 92A 73J | (12.11.2021)
– Store the dust extractor in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake (13) down to hold the castors (14)
in place.
Corrective measures
The mode selector switch (6) is set to "automatic start/stop".
– Set the mode selector switch (6) to the "extraction" symbol or switch on the
power tool plugged into the electric socket (4).
– Empty the container (1).
– Switch the dust extractor off and wait five seconds before switching it back on.
– Clean the fill level sensors (35) and the space between the fill level sensors (35)
using a brush.
– Remove any blockages from the vacuum nozzle, suction tube (29), vacuum hose
(21) or flat-pleated filter (24).
– Change the disposal bag (23) or dust bag.
– Make sure the filter cover (34) is engaged correctly.
– Place the top part of the dust extractor (10) on correctly and close the catches
(11).
– Change the flat-pleated filter (24).
– Check that the flat-pleated filter (24) has been fitted correctly.
– Change the flat-pleated filter (24).
– Clean the fill level sensors (35) and the space between the fill level sensors (35)
using a brush.
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
– Activate the automatic filter cleaning function (press the AFC button (3)).
– Connect the vacuum hose (21).
– Contact an authorised Bosch after-sales service centre.
– Contact an authorised Bosch after-sales service centre.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
Bosch Power Tools