NASAL SHOWER RHINO CLEAR® INSTRUCTIONS FOR USE
Before each use, wash your hands thoroughly and sanitize RHINO CLEAR® as de-
scribed in section "CLEANING, SANITIZATION, DISINFECTION". During the applica-
tion it is recommended to be adequately protected against dripping.
1. Plug the power cord (A6) into a power socket corresponding to the voltage of the unit. This
must be positioned so that it is not difficult to make the disconnection from the mains.
2. Remove the adapter (C6.1, C6.2, C6.3) and the separator (C6.4). Place the solution (max
10 ml) in the nebulizing chamber (C6.6.1) after having inserted the atomizer (C6.5) .
3. Apply the separator (C6.4) verifying that the arrow on the shower body is aligned with
the separator (Assembly diagram). Then, insert the correct adapter for your age, or the
most appropriate to fit the size of your nostrils (C6.1, C6.2, C6.3).
4. Connect the RHINO CLEAR® device through the tube (B) and the fitting (C7).
5. Turn on the device using the switch (A1)
6. Place the device close to the nose and gently insert the adapter nosepiece into one
ostril.
7. During treatment it is preferable to hold the other nostril closed, where the shower is
not applied, by applying light finger pressure.
8. Run the shower holding down the manual dispensing button (C6.7) during the inhala-
tion phase and release it before exhaling; at this stage, to help expel the mucus, blow
gently through the nostril treated directly into the RHINO CLEAR®.
9. Repeat from Step 6 to Step 8 for the other nostril, trying to evenly distribute the solu-
tion between the two nostrils.
10. When used on children or other dependent people, or in any case when there are
problems in coordinating the various phases of paragraph 8., we recommend to run
the application alternating the nostrils about 20 seconds each, with pauses required to
expel the mucus.
11. The operations described in the preceding paragraphs is useful for nasal cleaning us-
ing physiological solutions. The treatment with drugs is advisable after a first cleaning
with physiological solution in order to achieve a more effective distribution of the drug
on the nasal mucosa.
12. After application, turn the device off and sanitize it following the instructions given in
"CLEANING, SANITIZATION, DISINFECTION".
RF7 DUAL SPEED NEBULIZER INSTRUCTIONS FOR USE
Before each use, clean hands thoroughly and clean the device as described in the
section on "CLEANING, SANITIZATION AND DISINFECTION". During use, it is advisable
to protect yourself from any dripping. It is recommended that each person use their
own nebulizer cup and accessories to prevent risk of infection due to contamination.
This device is suitable for the administration of medical substances and not, for
which the administration via aerosol is foreseen; these substances are to be in any
case prescribed by the Doctor. In case of too thick substances, the dilution with a suit-
able physiological solution could be needed, according to the medical prescription.
1. Plug the power cord (A6) into a power socket corresponding to the voltage of the unit.
This must be positioned so that it is not difficult to make the disconnection from the
mains.
2. Insert the nozzle (C1.2) in the upper part (C1.3) pressing as shown by the 2 arrows in the
"Connection diagram" in point C1. Insert the Speed selector (C1.4) in the upper part (C1.3)
as shown in the "Connection diagram" in point C1. Pour the medication prescribed by
the doctor into the lower part (C1.1). Close the nebuliser by turning the upper part (C1.3)
clockwise.
3. Connect accessories as indicated in the "Connection diagram" on the cover.
4. Sit comfortably holding the nebuliser in your hand, place the mouthpiece onto your
mouth or alternatively use the nose piece or mask. Should you opt for the mask
12