SUB-ZERO BUILT-IN REFRIGERATION
BUILT-IN INSTALLATION
The importance of the installation of the
Sub-Zero Built-In unit cannot be overempha-
sized. Installation should be done by a qualified
installer.
Before you begin the installation process, it is
recommended that you read this entire Installa-
tion Instructions book. There are key details that
you should take special care to observe during
the installation. By reading these instructions
carefully, you will make the installation process
easier, problem-free and, most importantly, safe.
Any questions or problems about the installation
should be directed to your Sub-Zero dealer. You
can also visit our website at subzero.com.
Important product information, including the
model and serial number of your unit are listed
on the product rating plate. The rating plate is
located at the top frame of the unit inside the
door. Refer to the illustration below.
Location of
rating plate
Rating plate location
®
SUB-ZERO
is a registered trademark of Sub-Zero, Inc.
All manuals and user guides at all-guides.com
TOOLS AND MATERIALS REQUIRED
The following is a list of tools and materials that
should be available for proper installation.
•
Phillips screwdriver set
•
Slotted screwdriver set
•
Torx drive screwdriver set
•
1.2 m of 6,35 copper tubing and saddle valve
for the water line (4200880)—do not use self-
piercing valves
•
Copper tubing cutter
•
Level—.6 m and 1.2 m recommended
•
Appliance Dolly able to support 317 kg and
adequate manpower to handle the weight of
the unit
•
Various sized pliers
•
Wrench set
•
Allen wrench set
•
8 mm hex bolt nut driver
•
Crescent wrenches
•
Cordless drill and assorted drill bits
•
Masonite, plywood, 3,2 mm pressed fiber-
board, cardboard or other suitable material to
protect finished flooring
•
Appropriate materials to cover and protect
the home and its furnishings during installa-
tion
Make sure that the actual equipment that was
shipped to you matches the design you are
expecting to install. The Sub-Zero Built-In line
offers the following design alternatives—
overlay/flush inset and stainless steel models.
The overlay/flush inset model has two design
applications—overlay and flush inset.
Each of these design options has specific instal-
lation requirements, which means it is vital that
the unit match your planning and space needs.
Before you begin the installation process, check
the exact model number you need against the
model number on the shipping carton.
If the unit you receive does not match your
requirements, contact your Sub-Zero dealer.
SITE PREPARATION
Make sure that the finished rough opening
where the Built-In unit is to be installed is
properly prepared. Refer to the Overall Dimen-
sions and Installation Specifications for your
specific model on the following pages. These
specifications are identical for the overlay/flush
inset and stainless steel applications. The instal-
lation specifications are different for the flush
inset application, whether you are using custom
panels or Sub-Zero accessory stainless flush
inset panels. Make sure that the rough opening
dimensions, door swing clearance, electrical
service and plumbing are correct for the model
you are about to install.
If you are installing two Built-In units side by
side in the overlay/flush inset or stainless steel
application, a separating filler strip is recom-
mended. Add the filler strip width to the finished
rough opening dimension. Complete the installa-
tion with the Anchoring Kit (7004656). Refer to
page 16.
For installation of two Built-In units side by side
in the flush inset application, a dual installation
kit will be necessary. Refer to page 15.
IMPORTANT NOTE: Built-in units installed side
by side in the flush inset application cannot use
Sub-Zero accessory stainless flush inset panels,
and must have opposing hinges.
IMPORTANT NOTE: To operate properly, the
door must open a minimum of 90°. Use a
minimum 76 mm filler in corner installations to
assure a 90° door opening. Allow enough clear-
ance in front of the unit for full door swing.
IMPORTANT NOTE: Make sure the floor under
the unit is level with the surrounding finished
floor.
As you read these Installation Instructions, take
particular note of the CAUTION and WARNING
symbols when they appear. This information is
important for the safe and efficient installation
of Sub-Zero equipment.
CAUTION
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
WARNING
states a hazard that may cause serious
injury or death if precautions are not
followed.
In addition, these Installation Instructions may
signal an IMPORTANT NOTE which highlights
information that is especially relevant to a
problem-free installation.