Product Description And Intended Use; Preliminary Checks; Installation And Electrical Connections - Comunello Automation DART SLIM SYNC Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Thank you for choosing a COMUNELLO AUTOMATION
product.
This manual provides all the detailed information required for
the knowledge and correct use of the equipment. It must be
read carefully at the time of purchase and consulted if there are
any doubts regarding its use or when maintenance is required.
The manufacturer reserves the right to make any modifications
to the item and to this document without prior notice.
WARNINGS
Please read this manual carefully before beginning installation
and carry out the procedures as specified by the manufacturer.
This installation manual is only intended for professional
personnel.
Anything not expressly included in these instructions is
prohibited.
In particular, your attention should be drawn towards the fol-
lowing warning:
• Disconnect power before making any electrical connections.

PRODUCT DESCRIPTION AND INTENDED USE

DART SLIM SYNC photocells are wall-mounted photocells
with a range of up to 20 metres under optimal conditions.
Coding of the transmitted signal, to be set at the time of instal-
lation, makes it possible to install 2 pairs of the same model
with no interference between them.

PRELIMINARY CHECKS

• Check that the item inside the packaging is intact and in
good condition.
• Ensure that the positioning of the photocells allows for cor-
rect installation and securing of the photocells (Fig. 2).
• Ensure that the photocells are positioned on parallel surfaces
and that they are all at the same height.
ELECTRICAL SPECIFICATIONS (RX AND TX)
Voltage
Maximum consumption
MAXIMUM optical range under optimal
conditions
TX power supply
RX power supply
TX consumption
RX consumption
Relay contact rating
Operating temperature
IP protection rating

INSTALLATION AND ELECTRICAL CONNECTIONS

Operation with facing transmitter and receiver. Double safety
relay.
• Proceed as shown in Figure 3-4.
• Depending on the cable routing position, drill holes in the
base in the prearranged area (see Fig. 4).
• Proceed as shown in Figure 5 using rawlplugs (Ø max 5 mm)
and corresponding screws (not included).
• Connect the cables from the control unit to the terminals us-
ing the following diagram.
TX Connections CN1 (Fig. 10)
1 – 12/24 Vac/dc.
2 – 0V.
RX Connections CN2 (Fig. 15)
1 – 12/24 Vac/dc.
2 – 0V.
3 – NC/NO contact.
4 – NC/NO contact.
• Apply silicone to seal the cable entry hole (Fig. 6).
• Before closing the photocell, check the alignment between
the receiver (RX photocell) and the transmitter (TX photocell).
The steady light of LED1 on the receiver (red light) confirms
alignment (Fig. 7).
• Clip the cover back on the base by first resting the top and
pressing downwards (see Fig. 8).
Photocell synchronisation (Coding selection "A" and "B")
• In the event of special installations, the photocell has two
operating channels coded "A" and "B" which gives the user
the option of installing 2 pairs of SYNC version photocells
with no interference between them.
The item is supplied with factory settings coded "A": Dip-
switch N°2 ofSW1 in the "OFF" position (Fig. 11).
Jumper J1 on the receiver in position "2-3" relay contact NC
(Fig. 16).
24Vac/dc
Both codings must be selected in the same way on both
35mA
the transmitting and the receiving ends at the time of
installation.
20 m
12-24Vac/dc
12-24Vac/dc
10 mA max
25 mA max
1A max at
30Vdc
-10 – 55 °C
54
TX
LED TX
SW1
CN1
J2
10
RX
3
2
1
1
2 3
J2
LED1
LED2
CN1
3
2
J1
1
15
2
ON
1
ON
1
2
OFF
OFF
11
12
A
B
A
B
2
ON
1
ON
1
2
OFF
OFF
13
14
1 2
3
1 2
3
J2
1
2 3
1
2 3
J1
J2
NA
NC
1 2
3
3
3
3
B
J2
2
2
2
2 3
1
1
1
1
A
16
17
J1
J1
3
3
2
2
1
1
J1

Publicidad

Tabla de contenido
loading

Tabla de contenido