close magazine cap.
6.
Completely load lead screw into screw channel. At
this point, check to see that screw is completely
set in feeding claw.At this time, if the screw cannot
be set because the bit has come down as far as
the driver guide, turn the main unit upside down
(driver guide is on top), and return the bit to its
designated position.
7.
Slowly close door until lever stops fully.
2
3
009766
OPERATION
How to Drive Screws
CAUTION:
The utilized air pressure must be between 260 -
•
320 PSIG (1.76 - 2.26 Mpa) . Do not repeatedly
drive screw(s) in on top of a screw that has been
already driven in.
This driver is not an impact gun, so it requires a
•
reasonable amount of pressing.
If the main unit is not pressed sufficiently, the
•
screw may not drive in flush to workpiece, or come
out.
Always press the end of the discharge nose at a
•
right angle onto the workpiece and then drive in
screw.
We
recommend
intermitent-drive action to ensure proper screw
driving.
(1)
009767
1. Screw channel
1
2. Lead screw
3. Feeding claw
that
you
use
009768
First, lightly press the end of the contact arm onto a
workpiece.
Next, pull the trigger.Here, do not release the trigger until
the motor stops running.Note that if the trigger is
released too soon, the screw may not be driven in flush
to workpiece, and/or the screw feed may be impaired.
Switching between intermitent drive and
continuousl drive
Intermitent Drive Method
009769
the
(1)
009767
Intermitent drive is where the contact arm is pressed
against a workpiece, and the trigger pulled to drive in
one screw.
Set the switching lever to the
"Intermitent Drive Mode".
(1)
Press contact arm against workpiece.
(2)
Pull trigger.
6
(2)
1. Lever
1
position to set driver to