STEP 1B - SURFACE MOUNTING
These instructions are for surface mounting your cabinet, supplied with surface side kit (USMK27D6P)
1. See below for location and dimension of specific model and electric rough-in.
2. Locate and drill four 3/16" holes through the indent line on the mounting bar into the wall. Be sure the mounting bar is level. Make
sure Z mounting bar is centered.
3. Use four #10 X 2" screws (SS674) provided to attach the Z bar mounting strip to the wall. You can pre-drill a 3/32" hole in the stud.
1
© 2019 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
Installation instructions
Field wiring
19-1/8"
(485mm)
Product
UC2748 = 48"
(1219mm)
UC2736 = 36"
(914mm)
UC2730 = 30"
(762mm)
6
2
3
Z Bar
SS674
Part no. 209-1311-rA rev. 06/13/19
1" x 3"