SPECIFICATIONS
Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .5,250 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,550 watts
AC Load Current at 120 Volts . . . . . . . . . . . . .29.6 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . 4 U.S. gallons (15 l)
Shipping Weight . . . . . . . . . . . . . . . . . . . . 130 lbs. (59 kg)
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
NOTE: Should you have questions about replacing
components on your Troy-Bilt generator, please call
1-888-611-6708 for assistance.
Engine Maintenance
See engine operator's manual for instructions.
CAUTION
Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
Maintenance
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
Improper treatment of generator can damage it and
shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Inspect cooling air slots and opening on generator.These
openings must be kept clean and unobstructed.
Data Tag
Data tag information is very important if you need help from
our Customer Service Department or an authorized service
dealer.
The data tag (Figure 9) is located on the engine support on
the muffler side of the generator. For future reference, please
copy the model, revision, and serial number of the generator
in the space below.
Figure 9 — Data Tag
MODEL
REV NO
SERIAL
13
Section
5
Copy Model
Number Here
Copy Revision
Here
Copy Serial
Number Here