Desde una placa con teclado se puede realizar un Reset de
parámetros a valores por defecto de fábrica. Ver la Tabla de
configuración a través del código QR disponible en la parte trasera
del amplificador o el manual de Programación Placas Direct, cod.
97701, en www.fermax.com.
RESTORE DEFAULT VALUES: Reset
RESET Mapping (call button code)
1. Reset amplifier: remove power.
2. Press the SW1 button, connect the power supply and maintain
the SW1 button pressed 5 seconds until you hear the reset
confirmation sound: beep-beep.
Lock release times
To change the lock-release times see:
- If using a button panel, see Voice assisted configuration.
- If a DIRECT panel (with keypad), these parameters are
programmed via the keypad.
Both instructions are available via the QR code on the back of the
amplifier or at www.fermax.com.
RESET Programming Code from keypad panels
You can reset the programming access code (if the previous one is
forgotten), to the default code.
Pag 35