Astralpool Heliox UV MP Serie Manual De Instalación Y Mantenimiento página 10

Ocultar thumbs Ver también para Heliox UV MP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MP 450W model
T. block
Control panel input
PE
2
POWER 240 VAC / 50-60 Hz. / 3-phase
3
4
PE
UV REACTOR BONDING
5
UV LAMP-1 OUTPUT
6
7
UV LAMP-2 OUTPUT
8
9
SW-11
10
SW-12
11
SW-21
12
SW-22
13
14
SI5004 FLOW SENSOR INPUT
15
16
17
UVC-SE RADIATION SENSOR INPUT
18
19
20
21
TM4411 / MBT5250 TEMPERATURE SENSOR INPUT
22
23
FLOW SWITCH INPUT
24
25
EXTERNAL STOP INPUT
26
27
28
WIPER DRIVER (LAMP 1)
29
30
31
WIPER DRIVER (LAMP 2)
32
(1)
Not supplied with the unit.
(2)
Not supplied with the unit. Bonding must be made with a solid copper conductor minimum No. 8 AWG (USA) / 6 AWG (Canada)
(3)
Default bridged input. We strongly recommend to interlock the UV
system with the recirculation pump contactor through one of its NO
auxiliary contacts.
(1)
Minimum recommended wire size
Model
240 V / 1-phase
MP 50W
3 x AWG 16 (3 x 1.50 mm
MP 80W
3 x AWG 16 (3 x 1.50 mm
MP 140W
3 x AWG 12 (3 x 4 mm
MP 300W
3 x AWG 12 (3 x 4 mm
MP 450W
240 V / 3-phase
2
)
N/A
2
)
N/A
2
)
N/A
2
)
N/A
N/A
3 x AWG 12 (3 x 4 mm
Cable
GROUND
PHASE (R)
(1)
PHASE (S)
PHASE (T)
(2)
GROUND
LP-045/1-1
RED
LP-045/2-1
RED
WHITE
LP-045/1-2
WHITE
LP-045/2-2
BLACK "1"
LP-045-1
BLACK "2"
BLACK "1"
LP-045-2
BLACK "2"
BROWN
EVC-005
WHITE
BLUE
WHITE
BROWN
EVC059
BLACK
GREY
BROWN
EVC-005
WHITE
BLUE
(3)
POTENTIAL-FREE CONTACT
(4)
POTENTIAL-FREE CONTACT
"1" (AC)
WPA-05/1
"2" (SIGNAL)
"3" (GROUND)
"1" (AC)
WPA-05/2
"2" (SIGNAL)
"3" (GROUND)
(4)
Input logics
2
)
9
Wire description
Wiper driver (WP-01)
Wiper driver (WP-02)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Heliox uv mp 50wHeliox uv mp 80wHeliox uv mp 140wHeliox uv mp 300wHeliox uv mp 450w58808 ... Mostrar todo

Tabla de contenido