2.- Clean and replace if necessary, the fiber filters inside.
3.- Mount again the grid in its position.
7.7. Installation of the WIPER DRIVER
During the installation of the wiper driver must always be ensured that all elements of shaft are correctly aligned with the existing mark [1] in
the UV reactor body, as shown in the following figure.
7.8. Control of system isolation and connections
FREQUENCY:
You need to check the circuit breaker located inside the control panel at least EACH TIME YOU REPLACE THE UV LAMP, by
pressing the TEST button located on its front.
You need to check the status of all connections, especially the lamp power and the grounding of both the control panel and the UV
reactor, EACH TIME YOU REPLACE THE LAMP.