5.7. Installation of the TM4411 / MBT5250 temperature sensor
The TM4411/MBT5250 temperature probe consists of a Pt-100 sensor that converts its response in a 4/20 mA analog signal. The
TM4411/MBT5250 sensor comes factory calibrated so that it is not necessary to make any process for recalibration at installation time.
Configuration with MBT5250 sensor
1.
Temperature sensor input "Temp." at the UV reactor.
2.
MBT5250 temperature sensor.
3.
MBTC-05 cable.
Screw the MBT5250 / TM4411 sensor on the position labelled as "TEMP" at the body of the UV reactor.
Connect the MBT5250 / TM4411 sensor with the MBT-05 / EVC005 cable supplied with the unit to the corresponding terminals at the terminal
block inside the control box. (see page 8-9).
Configuration with TM4411 sensor
1.
Temperature sensor input "Temp." at the UV reactor.
4.
TM4411 temperature sensor.
5.
EVC005 cable.
Fig. 4
13