5.4. UV lamp connection
Connect the UV lamp(s) installed within the UV reactor to the corresponding terminals on the control panel using the cables supplied with the
unit (LP-0XX) (see page 8-9). To do this, open the connection boxes on both sides of the UV reactor, and connect the wires to the
corresponding terminals:
1.- Lamp power (red).
2. Microswitch (black wires, labelled "1" and "2").
Warning
Unit is equipped with an automatic mechanism for shutting off the power of the UV lamp
whenever the cover is removed.
Once the connection is made, close the connection boxes, making sure the seal is properly seated.
Should also connect the ground wire to the TWO bonding lugs marked
(US) and No. 6 AWG (Canada), and secure to the chamber by paint breaking washer and nut.
Warning
Prior to the installation or replacement of any system component make sure it has been
previously disconnected from the mains, and there is no water flow through it.
Check all the electrical connectors are well tightened to avoid false contacts and their
consequent overheating.
(*)
on the end flanges of the UV chamber suitable for No. 8 AWG