Installation Location; Installing The Indoor Unit - Mitsubishi Electric Mr.SLIM PKA-RP60KAL Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66

2. Installation location

PKA-RP60, 71, 100KAL
B
L
M
F
G
Fig. 2-1

3. Installing the indoor unit

1
2
4
5
7
8
0
Fig. 3-1
PKA-RP60, 71, 100KAL
F
H
15.5
0
25
50
75
100
117
125
142
192
242
279.5
292
C
A
K
Fig. 3-2
B
A
C
E
D
Fig. 3-3
(mm)
1170
A
C K
D
E
*
H
3
6
9
G
A
E
100m
I
J
A Sleeve
B Hole
C (Indoors)
D Wall
E (Outdoors)
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and
maintenance.
PKA-RP60, 71, 100KAL
A
Min. 100.5
Min. 22.4
F Air outlet: Do not place an obstacle within 1500 mm of the air outlet.
G Floor surface
H Furnishing
I When the projection dimension of a curtain rail or the like from the wall exceeds 60 mm,
J
extra distance should be taken because the fan air current may create a short cycle.
J 1800 mm or greater from the floor surface (for high location mounting)
I
K 108 mm or greater with left or rear left piping and optional drain pump installation
L 550 mm or greater with optional drain pump installation
M Minimum 7 mm: 265 mm or greater with optional drain pump installation
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PART NUMBER
1
Mount board
Tapping screw 4 × 25
2
Felt tape
3
4
L-shaped connection pipe
Charge nut
5
6
Wireless remote controller
Remocon holder
7
Alkali batteries (size AAA)
8
Tapping screw 3.5 × 16
9
0
Spacer
3.2. Installing the wall mounting fixture (Fig. 3-2)
3.2.1. Setting the wall mounting fixture and piping positions
Using the wall mounting fixture, determine the unit's installation position
(mm)
and the locations of the piping holes to be drilled.
Warning:
B
Before drilling a hole in the wall, you must consult the building contractor.
54
25
0
12.5
PKA-RP60, 71, 100KAL
37.5
62.5
87.5
A Mount board 1
104.5
129.5
B Indoor unit
167
C Bottom left rear pipe hole (ø75-ø80)
217
229.5
D Bottom right rear pipe hole (ø75-ø80)
264
E Knockout hole for left rear hole (75 × 480)
292
308.5
311
F Bolt hole (4-ø9 hole)
D
G Center measurement hole (ø2.5 hole)
H Tapping hole (75-ø5.1 hole)
I Hole centre
J Align the scale with the line.
K Insert scale.
3.2.2. Drilling the piping hole (Fig. 3-3)
Use a core drill to make a hole of 75-80 mm diameter in the wall in the
piping direction, at the position shown in the diagram to the left.
The hole should incline so that the outside opening is lower than the
inside opening.
Insert a sleeve (with a 75 mm diameter and purchased locally) through the
hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
B
C
D
Min. 48
Min. 250
QUANTITY
ACCESSORY
60, 71, 100
1
7
2
1
1
1
1
2
2
1
(mm)
E
Min. 220
LOCATION OF
SETTING
Fix at the back of the
unit
Make use of
packaging material
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mr.slim pka-rp71kalMr.slim pka-rp100kal

Tabla de contenido