Technical Data

Code
Description
Voltage and Frequency
Power
Current
Speed
Flow Rate
Maximum Depth
Maximum Height / Maximum
Value of Total Gauged Height
Power Cable
Allows Particles Up To
IP Grade
Conductors
Insulating
WARNING
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING

Power Requirements

WARNING
The equipment shall be grounded while in use to prevent an electric shock.
• Connect plug into a properly grounded contact or outlet as shown in
example A. Not all contacts or outlets are properly grounded. If not sure,
contact with a certified electrician.
• If the outlet you want to use with the equipment has two poles (2 orifices),
FOR ANY REASON AT ALL DO NOT REMOVE OR ALTER THE PLUG'S EARTH
TERMINAL. Use a temporary adapter as shown in example B and always
connect the earth conductor's lug as indicated.
CAUTION
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows
the right size to use depending on cable's length and the ampere capability
shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
* It is safe to use only if the extensions have a built-in artifact for over current protection. AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
WARNING
When operating power tools outdoors, use a
"For Outdoors Use". These extensions are especially designed for operating outdoors and reduce the risk of
electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall be in
compliance with the Mexican Official Standard NORMA OFICIAL MEXICANA NOM-001-SEDE,
INSTALACIONES ELÉCTRICAS (UTILIZACIÓN) or with the local codes and municipal by-laws.
BOS-1/2LP
12601
1/2 Hp
2.8 A
28.6 gal/min
16.4'
26.2'
26.2'
18 AWG x 3 C with 221 ºF insulating temperature .
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
Before gaining access to the terminals all power sources should be disconnected.
Number of
Conductors
3 (one grounded)
BOS-3/4LP
12600
Submersible Pump for Clean Water
120 V
60 Hz
3/4 Hp
4 A
2 850 RPM
44 gal/min
22.9'
27.8'
32.8'
3/16"
IPX8
Class I
Power cord grips used in this product: Type "Y".
Build quality: Basic insulation
Thermal insulation on motor winding: Class B
Authorized Service Center.
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled
BOS-1LP
12602
1 Hp
6 A
55 gal/min
26.2'
32.8'
36'
A
B
CAUTION
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3