INSTALLATION
WARNING: To reduce the risk of fire, do not store or use gaso-
line or other flammable vapors and liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of fire, keep electrical cords,
drapery, furnishings, and other combustibles at least 3 feet (0.9
m) from the front of the heater and away from the side and rear.
1.
Mark the intended mounting location in the base plate under the
counter or kickspace, and remove required material to provide
for easy insertion and removal of the heater cabinet.
2. The unit will be secured in place with screws through the side
angle support brackets. Provide adequate material behind side
angle support for secure mounting.
FIELD CONVERSION TO 120 V.A.C.
If a 120 V.A.C. circuit is to be used, make wiring changes as follows:
1.
Disconnect white wire from heater element terminal "2" and
connect it to terminal "4." The heater will now operate at 120
V.A.C., 750W, 6.3A.
2. For 120 V.A.C, 1500W, 12.5A operation, add the short red jumper
wire (provided) between terminals "1" and "2" .
3. Remove alarm light wire leads from terminals "1" and "3" of
the high temperature limit. Remove white wire lead from limit
terminal "1" and reconnect at limit terminal "3" . Secure wire leads
with wire tie so there is no interference with unit operation.
NOTE: Terminal numbers are marked on the side of the blower
housing, above the heater elements.
SIDE ANGLE
SUPPORT BRACKETS

THERMOSTAT INSTALLATION

NOTE: The thermostat control circuit must be wired prior to the
wiring of the heater unit.
This heater may be thermostatically controlled by either a line volt‑
age wall‑mounted thermostat (Model 86W), or an optional built‑in
thermostat accessory kit (Model 90). Model 90 thermostat kits are
designed for easy installation with this heater. Instructions for in‑
stalling thermostats are provided below and are also supplied with
each thermostat kit.
OPTIONAL LINE VOLTAGE WALL-MOUNT THERMOSTAT
1.
Locate thermostat on an inside wall away from all drafts and
approximately 4‑5 feet above the floor.
2. Route all wiring through the thermostat first and then to the
heater.
OPTIONAL (MODEL 90) UNIT-MOUNT THERMOSTAT
1.
Remove the top cover from the heater.
2. Remove the 5/8" knockout located on the left side of the front
panel (use a screwdriver to remove the knockout). Also remove
the two plastic hole plugs (see illustration).
MODEL 114
Page 2