Assembling the drinking water telescopic dome shaft

6.1
Assembling the drink-
ing water telescopic

dome shaft

Prior assembly, the enclosed
seal is locked onto the tank
neck's profile „B". The tank
dome is then locked to the tank
neck. It is essential to make
sure that the upper seal "A"
(pre-assembled)
is
correctly
installed.
A
6.2

Drinking water telescopic dome shaft

Imp ortant: To prevent loads from being transferred onto the
tank, round-grain gravel
layers around the drinking water telescope
compacted. Damage to the tank dome
be avoided during this step. The cover is then positioned
and is sealed to prevent entry by children. Tighten the
threaded connection on the cover so tightly that it cannot
be opened by a child! For a professional installation of a
drinking water cover, the telescopic dome shaft must reach
about 20 cm above the ground level.
6.3

Drinking water lid

The drinking water telescope is provided with a sec-
ond lid that rests on top. This is also always placed
on the rim of the telescope, except when working in
the tank.
The seal must be in place in the groove around the
entire circumference before the lower telescope lid is
positioned.
ATTENTION: The upper drinking water lid serves
only as a protective cover and is not safe to walk
on!