Before Returning For Repairs - Schumacher Electric SC10 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
The BAD BATTERY
LED is lit and the
CHARGING/BOOST/
ENGINE START LED is
flashing.
The BAD BATTERY
LED is lit.

14. BEFORE RETURNING FOR REPAIRS

For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.
15. SPECIFICATIONS
Input ................................................. 120V AC @ 60Hz, 2.2A continuous, 12A intermittent
Output ..............................................................................................6V DC, 2A continuous
6/12V DC, 55A intermittent; 5 seconds maximum on, 180 seconds minimum off
POSSIBLE CAUSE
The battery voltage is still
below 10V (for a 12V battery)
or 5V (for a 6V battery) after 2
hours of charging.
(or)
In maintain mode, the output
current is more than 1.5A for 12
hours.
Desulfation was unsuccessful.
The battery is sulfated.
Lack of progress is detected
and battery voltage is below
14.2V (for a 12V battery) or
7.1V (for a 6V battery).
The battery's initial voltage
is below 12.2V (for a 12V
battery) or 6.1V (for a 6V
battery) and the total input is
less than 1.5 Ah.
The battery voltage drops
to below 12.2V (for a 12V
battery) or 6.1V (for a 6V
battery) in Maintain Mode.
If these solutions do not eliminate the problem,
or for more information about troubleshooting,
contact customer service for assistance:
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
The battery may be defective.
Make sure there are no loads on
the battery. If there are, remove
them. If there are none, have the
battery checked or replaced. To
reset the charger, unplug from the
AC outlet, wait a few moments and
plug it back in.
The battery may be defective. Have
battery checked or replaced.
The charger is in desulfation mode.
Continue charging for several
hours. If not successful, have the
battery checked.
The battery may be overheated. If
so, allow the battery to cool. The
battery may be too large or have a
short circuit. Have battery checked or
replaced.
The battery capacity is too low,
or the battery is too old. Have it
checked or replaced.
The battery won't hold a charge.
May be caused by a drain on the
battery or the battery could be bad.
Make sure there are no loads on
the battery. If there are remove
them. If there are none, have the
battery checked or replaced.
to 5:00
CST
am
pm
12V DC, 6<>2/10A continuous
• 8 •
REASON/SOLUTION

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido