Before Returning For Repairs - Schumacher Electric XC75 Manual Del Usuario

Ocultar thumbs Ver también para XC75:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Short or no start cycle when
cranking engine.
I cannot select a 6V or 12V
setting.
14. SPECIFICATIONS
XC75 and XC75W
Input Voltage ...................................... 120V AC @ 60Hz, 3.5A continuous / 13.8A intermittent
Output Voltage .............................................................6V or 12V, with Auto Voltage Detection
Output Current Rating........................................ 3A/5A/10A continuous / 20A/75A intermittent
XC103 and XC103W
Input Voltage ......................................... 120V AC @ 60Hz, 4A continuous / 18.6A intermittent
Output Voltage .............................................................6V or 12V, with Auto Voltage Detection
Output Current Rating..................................... 3A/5A/12A continuous / 30A/100A intermittent

15. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number from
Customer Service at Schumacher Electric Corporation.
POSSIBLE CAUSE
Drawing more than the
engine start rate.
Failure to wait 3 minutes (180
seconds) between cranks.
Clamps are not making a
good connection.
The charger may be
overheated.
Battery may be severely
discharged.
The charger is equipped
with Auto Voltage Detection,
which automatically detects
the voltage and charges the
battery.
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
• 10 •
Crank time varies with the
amount of current drawn. If
cranking draws more than the
engine start rate, crank time
may be less than 3 seconds.
Wait 3 minutes of rest time
before the next crank.
Check for poor connection at
battery and frame.
The thermal protector may
have tripped and needs a little
longer to close. Make sure the
charger vents are not blocked.
Wait and try again.
On a severely discharged
battery, charge for 10 to
15 minutes at the FAST
charge rate to help assist in
cranking.
No problem; this is normal.
to 5:00
CST
am
pm
SOLUTION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xc75wXc103Xc103w

Tabla de contenido