Remedy of faults

S
Malfunction
The unit does not start up
Insufficient fountain height
Unit switches off after a short running period

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
If necessary, clean the unit with clear water using a soft brush.
• In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
• Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Replacing impeller unit
7.
How to proceed:
0.
D
1. Remove four screws and take off the pump casing.
2. Use a wide-blade screwdriver to lever the impeller unit out of its position in the motor housing.
− Insert the screwdriver blade into the groove between the impeller unit and motor housing, and firmly turn the
screwdriver in order to dislodge the impeller from its position.
− Proceed carefully so as not to damage the motor housing or O ring.
3. Assemble the pump in the reverse order.
− Firmly push the impeller unit into position in the motor housing.
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
12
37818-02-14_GA_PondoCompact_200012 12
Cause
No mains voltage
Impeller unit blocked
Regulator closed too far
Filter housing or impeller unit soiled, hose
blocked
Hose defective
Hose kinked
Impeller unit worn
Filter clogged
Water temperature too high
Remedy
Check the mains voltage
Clean
Adjust regulator
Clean
Replace
Route hose in a straight line
Replace impeller unit
Clean
Adhere to max. permissible water temperature
(→ Technical Data)