- EN -
Commissioning/start-up
NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.
Only operate the pump when it is immersed.
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.
Malfunction remedy
Malfunction
The unit does not start up
Insufficient fountain height
Maintenance and cleaning
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-
tion of the device and harm animals, plants and the environment.
Clean the device only with clear water and a soft brush or sponge.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
Replacing the impeller unit
How to proceed:
D
1. Pull off the pump casing.
2. Pull the impeller unit out of the motor housing.
3. Assemble the pump in the reverse order.
Replacing the bulb
PondoCompact 300iL is equipped with integrated lighting.
How to proceed:
E
1. Carefully pull the glass tube from the lamp socket.
2. Pull the defective bulb out of the lamp socket and fit a new bulb.
– Only use approved bulbs: → Technical Data
– Do not touch the bulb with your fingers, use a cloth.
3. Fit the glass tube onto the lamp socket.
– Ensure that the O rings at the lamp socket are clean and undamaged.
10
Cause
No mains voltage
Impeller unit blocked
Regulator closed too far
Pump casing or impeller unit soiled, hose
blocked
Hose defective
Hose kinked
Impeller unit worn
Remedy
Check the mains voltage
Clean
Adjust regulator
Clean
Replace
Route hose in a straight line
Replace impeller unit