5. Specifications
BlueSolar Charge
Controller
Battery voltage
Rated charge current
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Maximum PV open circuit
voltage
Max. PV short circuit current 2)
Maximum efficiency
Self-consumption
Charge voltage 'absorption'
Charge voltage 'equalization' 3)
Charge voltage 'float'
Charge algorithm
Temperature compensation
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
STANDARDS
Safety
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the controller in case of reverse polarity connection of
the PV array.
3) Default setting: OFF
MPPT 100/30
30A
440W
880W
100V
35A
98%
12V: 30 mA
Default setting: 14,4V / 28,8V (adjustable)
Default setting: 16,2V / 28,8V (adjustable)
Default setting: 13,8V / 27,6V (adjustable)
multi-stage adaptive (eight preprogrammed algorithms)
-16 mV / °C resp. -32 mV / °C
PV reverse polarity, Output short circuit
-30 to +60°C (full rated output up to 40°C)
5000m (full rated output up to 2000m)
Indoor type 1, unconditioned
VE.Direct (see the data communication white paper
ENCLOSURE
IP43 (electronic components),
EN/IEC 62109-1 / UL 1741 / CSA C22.2 NO.107.1-16
13
MPPT 100/50
12/24V Auto Select
1400W
24V: 20 mA
or user defined algrithm
Over temperature
95%, non-condensing
PD3
on our website)
Blue (RAL 5012)
13 mm² / AWG6
IP22 (connection area)
1,3 kg
130 x 186 x 70 mm
50A
700W
100V
60A
98%

Publicidad