maintenance shall not be made
by children without supervision.
Safety during installation
Fan equipment should be electrically isolated
and locked out before any work started.
Before any installation work is started, ensure
that fan equipment is correct for application.
Location for installation is solid, level, fl at and
suitable for mounting fan assembly.
Fan should be located in position, and assem-
bled with any accessory equipment supplied, on
relevant mounting, anti-vibration mountings,
safety protection guards, on a solid level base to
avoid any distortion and misalignment and with
correct air direction as shown on nameplate.
Fan should then be levelled on any anti-vibra-
tion mountings. Flexible connectors must be
taught to ensure no disruption to air fl ow, espe-
cially on inlet to fan.
Make sure there are no loose elements near the
fan. When the fan is mounted in a duct, check
that it is clean of any elements and exclusively
used for ventilation system.
For electrical connections follow the wiring dia-
gram indicated in this manual.
Start up
Check fan equipment name plate data is appro-
priate to the location electrical supply, espe-
cially Voltage, Frequency, Phase, Amps, speed
are correct.
Check earth connections, electrical termina-
tions and terminal box lid, with any seals, if fi t-
ted, are correct.
In compliance with Machine Directive 89/392/
EU, if the fan is accessible to operators and is
a health and safety risk, adequate protection
must be fi tted, information for safety equip-
ment, including guards, can be found in S&P
accessories catalogue.
Check all rotating parts have free, unobstructed
movement.
Check there are no foreign bodies inside the fan
or that can be drawn into, or fall into fan.
Check the structure is complete and has no
damage. Check installation and area is safe and
energise fan and start motor.
Check that the impeller and airfl ow direction is
correct, and there are no unusual vibrations.
Check current does not exceed fan equipment
nameplate data.
Electrical connection is in accordance with the
wiring diagram included in the manual (voltage
regulation allowed only on HS – terminal LA).
If any of the electrical safety devices blow, the
fan must be quickly disconnected from the
mains supply. The whole installation should be
carefully checked before trying to start up the
fan again. After two hours of operation, check
that all fi xings are tight and adjust if necessary.
Maintenance
Maintenance/repairs must be carried out by
competent personnel and in accordance with
applicable International, National and Local
regulations. Fan equipment should be electri-
cally isolated and locked out before any work
started.
Fan equipment should be regularly cleaned,
frequency depending upon service load and ap-
plication, but no less than every year. Cleaning
should include all areas where dust can accu-
mulate in the fan equipment.
Special attention should be made to any unusu-
al sounds, vibration or temperature. If any prob-
lems are detected the fan equipment should
be stopped immediately and cause inspected.
The impeller and blades should be regularly
checked for damage that could cause imbal-
ance in the moving parts
Recycling
In accordance with EEC Standards and our
responsibility for future generations, we are
obliged to recycle all the materials we can.
Therefore, please deposit all waste material
and packaging in their corresponding recycling
containers and hand in the replaced units to the
nearest handler of this type of waste product.
To clarify any questions regarding S&P products
contact your local distributor. For its location and
to obtain the EU Declaration of Conformity certifi ed
technical data sheet and copy of this instruction
manual, see our web site www.solerpalau.com.
9