Futurelight PHW-750E Manual Del Usuario página 41

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
Before taking into operation for the first time, the installation has to be approved by an expert!
(1) Omega-holders
(2) Clamp
(3) Safety-rope
(4) Quick-lock fastener
Screw one clamp each via a M12 screw and nut onto the Omega-holders.
Insert the quick-lock fasteners of the first Omega-holder into the respective holes on
the bottom of the device. Tighten the quick-lock fasteners fully clockwise. Install the
second Omega-holder.
DANGER TO LIFE!
41/110
00031483.DOC, Version 1.0

Publicidad