1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wings should start an opening movement.
If this is not the case, invert the movement wires of the motor. (4<>6 for motor M1, and 7<>9 for motor M2) and the relevant limit
switch inputs (22<>23 for motor M1, and 24<>25 for motor M2).
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One
segment of the display is linked to each input. In the event of failure it switches on according to the following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal segments.
For example, with the leaves
completely closed the display
is as follows:
PRG
The value is programmed
Pre
When programming has been made, the display goes to the function just set
Press <+> and <-> simultaneously to go to the higher menu and quit programming or wait
PAR
30s.
TO CHECK CONNECTIONS:
������
����
the moment an Open impulse
is given:
DIAGNOSTICS
������
������
������
����
���
����
�����
����
����������
���
during the opening phase:
with the leaves completely
open: