MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter
impulse has no effect during the opening phase.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the
SCL
intervention of the photocell causes automatic closing after 3 s. Active only with
TCA:ON.
Off: rapid closing disabled.
Enables or disables slowing.
Sld
On: Slowing active.
Off: Slowing excluded.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the inversion stroke function
On: Function enabled. Before each opening or closing manoeuvre the control
HAM
unit orders a manoeuvre of 2s in the opposite direction to facilitate the release
of the electric lock.
Off: Function disabled.
Enables or disables the block maintaining function.
Recommended for hydraulic motors to keep the leaf resting against the me-
chanical stop block.
BLC
On: Block maintaining function enabled. Every 2 hours the control unit makes a
closing manoeuvre with a duration of about 3s to keep the leaf in contact.
Off: Block maintaining function disabled.
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor
SPN
operates at maximum torque.
Off: Starting torque disabled.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
Selects the mode of the OPEN input
On: OPEN input with CLOCK function.
CLOC
To be used for connection to a timer for timed opening/closing. (Contact
CLOSED- gate open, Contact open, normal operation).
Enables or disables Man present function.
On: Man Present operation.
htr
The OPEN/CLOSE buttons must be held down during the whole manoeuvre.
Off: Automatic operation.
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vac.
Before each opening manoeuvre the power supply is interrupted for the time
mloc
set by the parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vac for the time set by the
parameter TLOC.
FUNCTION
Settable values
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
11