Beninca brain Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want.
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 60s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and clos-
TM1
ing manoeuvre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and clos-
TM2
ing manoeuvre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Pedestrian opening time.
TPed
Regulates the duration of the pedestrian opening manoeuvre of the motor 1.
Motor 1 torque. Regulates the torque applied on the motor 1.
PM1
RESPECT THE REGULATIONS IN FORCE!
Motor 2 torque. Regulates the torque applied on the motor 2.
PM2
RESPECT THE REGULATIONS IN FORCE!
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
TLS contact activation time.
TLS
At each manoeuvre the contact closes for the set time.
Electric lock activation time.
TLOc
If the electric lock is not used, set the parameter at 0.
Motor 1 slowing time
Regulates the duration of the slowing phase of motor 1 on opening and clos-
TsM1
ing. The set time is subtracted from the motor 1 work time (TM1), which must
always be higher.
Motor 2 slowing time
Regulates the duration of the slowing phase of motor 2 on opening and clos-
TsM2
ing. The set time is subtracted from the motor 2 work time (TM2), which must
always be higher.
Motor 1 slowing torque
Psl1
Regulates the torque applied to motor 1 during the slowing phase
Motor 2 slowing torque
Psl2
Regulates the torque applied to motor 2 during the slowing phase
10
TO ACCESS PROGRAMMING
NOTES
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
FUNCTION
Settable values
MEMO
MIN-MAX-(Default)
1-240-(40s)
5-180-(24s)
5-180-(24s)
5-180-(10s)
1-99-(40%)
1-99-(40%)
0-15-(2s)
0-40-(3s)
1-240-(60s)
0-5-(3s)
1-30-(7s)
1-30-(7s)
1-99-(70%)
1-99-(70%)

Publicidad

Tabla de contenido
loading

Tabla de contenido