Bradley 500 Serie Manual De Instalación página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
5b
Pilasters and Panels with Aluminum Continuous Brackets (Optional)
Pilasters located at walls should be mounted first. Start at one end and install a panel, then a pilaster. Continue alternating until
installation is complete. When installing in an alcove or in-corner, use an alcove bracket to secure the pilaster to the panel.
Check to make sure the pilasters are plumb and level to each other. The pilaster height can be adjusted by moving the
support nuts on the wedge anchor up or down (see page 7).
Pilasters at Wall
When installing pilaster at walls, the gaps range
from 1/2" to 1-1/4" (13mm to 32mm). Refer to your
submittal drawing for your gap sizes.
Slide the shoe onto the bottom of the pilaster and
use a piece of tape to keep the shoe positioned
A
above the mounting hardware . Make sure the shoe
mounting hole is facing inside the stall and that the
hole is towards the top .
Set the pilaster onto the mounting hardware while
at the same time placing the pilaster within the
B
wall bracket . Secure the pilaster to the mounting
hardware using the 13/32" x 3/4" washer(s), spacer
nut(s), and 3/8" hex nut(s) provided .
Using the bracket as a template, drill Ø1/4" holes
C
through the pilaster at each pilaster bracket hole .
Secure the pilaster to the bracket using the
#10-24 x 3/4" stainless barrel nuts and #10-24 x 1"
stainless shoulder screws provided .
12
3/22/2018
Pilasters with Panels
Refer to your submittal drawing and leave the appropriate
gaps. Standard gap is 1" (25mm) between the panel and
wall and 1/2" (13mm) between the panel and pilaster.
A
Place the panel on the spacer and insert the panel into the
wall bracket .
Slide the shoe onto the bottom of the pilaster and use a piece
B
of tape to keep the shoe positioned above the mounting
hardware . Make sure the shoe mounting hole is facing inside
the stall and that the hole is towards the top .
Set the pilaster onto the mounting hardware while at the same
C
time placing the bracket around the panel . Secure the pilaster
to the mounting hardware using the 13/32" x 3/4" washer(s),
spacer nut(s), and 3/8" hex nut(s) provided .
Spacer 12" (305mm)
Using the bracket as a template, drill Ø1/4" holes through the
D
panel at each panel bracket hole . Secure the panel to the
bracket using the #10-24 x 3/4" stainless barrel nuts and
#10-24 x 3/4" stainless shoulder screws provided .
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Installation

Publicidad

Tabla de contenido
loading

Tabla de contenido