Installation
7
Wraparound Gravity Hinges (Continued)
The door hinge assembly consists of separate door
and pilaster hardware.
Door cam surfaces can become worn under normal use.
The application of lithium grease can help prolong door
cam life and reduce friction between surfaces.
Secure the top and bottom pilaster hinge to the pilaster
C
with the #10-24 x 3/4" barrel nuts and #10-24 x 1"
shoulder screws provided .
Assemble the bottom hinge cam and pin as shown .
D
Insert into the bottom hinge and thread the locknut
loosely onto the bottom hinge pin .
Place the bottom door hinge opening onto the bottom
E
pilaster hinge . Position the top door hinge opening into
the top pilaster hinge and insert the top hinge pin .
The top hinge pin should snap securely
into place.
Rotate the door to the desired "at rest" position . Push
F
down on the door while maintaining the desired "at rest"
position . This sets the male and female cams in the
bottom hinge . Tighten the hex nut to secure the door in
the "at rest" position .
For doors requiring a full close, rotate the
door 15° past the closed position.
Finished View
of Top Hinge
Finished View
of Bottom Hinge