Bradley 500 Serie Manual De Instalación página 28

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
9b
Urinal Screens with Continuous Aluminum Brackets (Optional)
Before installing the urinal screen components, determine the correct location for your application.
Brackets are used as templates, but since the hole patterns may be different, the brackets
may not be interchangeable.
Draw a plumb line on the wall to represent the urinal screen
A
centerline . Measure from the highest point in the room and place
a mark on the urinal screen centerline at dimension "A" for the
respective urinal screen height (see table below) .
Place the bottom of the bracket on the mark and center the
opening on the urinal screen centerline . Using the bracket as
B
a template, mark the hole locations on the wall . Remove the
bracket and drill a Ø5/16" hole (minimum 2" [51mm] deep) at
each hole location .
C
Insert plastic anchors in all holes and secure bracket to the wall
with the #14 x 2" stainless screws provided .
Place the urinal screen at dimension "B" for the respective
D
urinal screen height (see table on right) and insert it into the
wall bracket until a 1" (25mm) gap between the wall and urinal
screen is established .
Using the bracket as a template, drill Ø1/4" holes through the
E
urinal screen at each bracket hole . Secure the urinal screen to
the bracket with the #10-24 x 3/4" stainless barrel nuts and
#10-24 x 3/4" stainless shoulder screws provided .
28
3/22/2018
42" Urinal Screen
18-1/4" (464mm)
48" Urinal Screen
15-1/4" (387mm)
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Installation
Urinal Plumb Line
"B"
"A"
Dim "A"
Dim "B"
18" (457mm)
12" (305mm)

Publicidad

Tabla de contenido
loading

Tabla de contenido