Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
7
Wraparound Gravity Hinges (Standard)
Before installing the hinges, make sure the door openings are the appropriate size, all pilasters are plumb and
secured to the floor.
Refer to your submittal drawings to determine each specific door swing for your application. The door swing is
determined by facing the compartment from the outside. The image below can help determine the door swing type.
Measure down from the top of the pilaster
and place a mark at dimensions "A" and "B"
A
for the respective pilaster type (see table
below) . This mark represents the upper hole
location of the top and bottom hinge .
For 58" wall hung pilaster, establishing dimensions "A" and "B" as shown in the
table will result in the top of the door being flush with the top of the pilaster when
the cam setting on the door is set to 0°.
18
Right-hand
Left-hand
inswing
inswing
(RHI)
(LHI)
Floor-Braced
"A"
3/22/2018
Right-hand
Left-hand
outswing
outswing
(RHO)
(LHO)
B
Using the hinge as a template, drill Ø1/4"
holes through the pilaster .
Wall Hung
58" (1473mm)
"B"
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
"A"
"B"
Dim . "A"
Floor-
2-1/16"
Braced
(52mm)
Wall Hung
2-1/16"
58"
(52mm)
(1473mm)
Installation
Dim . "B"
56-3/16"
(1718mm)
56-3/16"
(1427mm)

Publicidad

Tabla de contenido
loading