GENERAL INFORMATION
GENERAL INFORMATION
3 IDENTIFICATION
The storage cylinders themselves and the complete system are
identified by:
Data plate
The
R
RPS 25/2 EVO solar water heating system is identified by
system data plates marked with the code, description and serial
number of the product.
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
SISTEMA - SYSTEME - SYSTEM - SYSTEEM
Mod.
Cod.
N°
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
Mod.
Cod.
N°
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
SOLARBOILER
SOLAR STORAGE CYLINDER
Modell
Herstell. Nr.
Model
Serial number
Artikel Nr.
Code
Leistungsaufnahme obere Rohrschlange
[Primärkreislauftemperatur T=80°C]
Power absorbed by top coil (T° primary 80°C)
Warmwasserbereitung - obere Rohrwendel [∆T 35°C]
Domestic hot water production – top coil [∆T 35°C]
Wärmetauschfläche obere Rohrwendel
Top coil heat exchange surface area
Wärmetauschfläche untere Rohrwendel
Bottom coil heat exchange surface area
Maximaler Boilerbetriebsdruck
Maximum working pressure of storage cylinder
Boilerfassungvermögen
Storage cylinder capacity
Elektrischer Leistung
MIN / MAX
Electrical consumption
Anschlussspannung
Power supply
Verluste nach EN 12897
Heat loss according to EN 12897
ERDUNG OBLIGATORISCH - OBLIGATORY GROUND CONNECTION
These plates also list the storage cylinder's technical specifica-
tions and performance.
They are supplied in the documentation envelope delivered
with the system and must be applied to the solar storage cylin-
der on completion of installation.
9
For the identification of the collectors, see the specific
handbook.
9
If these plates or any other means of clearly identifying the
product are defaced, removed or lost, proper installation
and servicing may be rendered difficult.
T067784ED
Baujahr
Year
kW
l/1'
m
2
m
2
bar
l
W
V-Hz
W
4 TECHNICAL SPECIFICATIONS
DESCRIPTION
Total exposed surface (A
sol
Energy consumption of
pump (solpump)
Consumption in stand-by
(solstandby)
Annual non-solar
Caloric contribution*
(Q
)
nonsol
Annual auxiliary electricity
consumption (Q
)
aux
(*) Value calculated in terms of primary electrical energy
and/or calorific content of fuel under average climatic
conditions, in load profiles M, L, XL and XXL, with
permanent backup and storage cylinder inside building.
9
For technical data about the individual components, see
the specific handbooks.
6
RPS 25/2 EVO
200
300
)
2,152
4,304
60
60
3
3
M
900
771
L
1852
1305
XL
3303
2451
XXL
4431
3441
146
146
m
2
W
W
kWh/a
kWh/a
kWh/a
kWh/a
kWh/a