Configuration - WIKA TR21-A Manual De Instrucciones

Termorresistencia miniatura
Ocultar thumbs Ver también para TR21-A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Configuration

7. Configuration
Configuration is carried out using a USB interface with a PC via the model PU-548
programming unit (accessories, order No. 14231581). The connection with the
thermometer is made via the appropriate adapter cable (accessories: M12 x 1 circular
connector, order No. 14003193).
Measuring range, damping, error signalling, TAG No. and other parameters can be
adjusted (see configuration software).
The measuring range is configurable between -50 ... +250 °C (-58 ... +482 °F). The
configuration software checks the required measuring range and will only accept
permissible values. Intermediate values are configurable - the smallest increment is 0.1 °C
or 0.1 °F. The thermometers are delivered configured to customer specifications within the
configurable limits.
Please note:
The measuring range of the thermometer is limited by the application range of the
measuring element, not by the setting range of the transmitter.
Maximum permissible temperatures:
At the case with transmitter: 85 °C (185 °F)
Temperature at the connector: max. 85 °C (185 °F)
Model TR21-A:
-30 ... +250 °C (-22 ... +482 °F)
Model TR21-B:
-30 ... +150 °C (-22 ... +302 °F)
Model TR21-C:
-30 ... +150 °C (-22 ... +302 °F)
-30 ... +250 °C (-22 ... +482 °F)
WIKA operating instructions model TR21
Easy to use
LED status display
Compact design
No further power supply is needed for either the
programming unit or for the transmitter
(replaces programming unit model PU-448)