AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 6 hours continuous operation. The follo ing
in the display:
the
button ¹ (see Section E).
AUTOMATIC CLEANING MODE
When the heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl:05 running back to cl:01. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
I
CHILDPROOF LOCK / PARENTAL CONTROL
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the heater
can only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater. Activate the childproof lock by pressing the appropriate key
it do n for more than 3 seconds. The KEY-LOCK indicator
information display ( ig. I), indicating that the childproof lock has been activated.
S itch off the childproof lock by pressing the key
than 3 seconds once again.
J
THE CORRECT USE OF 'SAVE'
The SAVE function allo s you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature exceeds
the set temperature by 3 C. Subse uently,
again to the set temperature, the heater will automatically switch on again. Activate
the SAVE setting by pressing the appropriate
light up ( ig. J). S itch off the function by pressing the SAVE key once again.
Without the SAVE setting your heater
!
appro imation as
ell, by adjusting its heating capacity. SAVE is an economy
setting, which you can use when, for instance, you are not present in the room
or to keep it frost-free.
K
THE 'FUEL' INDICATOR
When the UEL indicator appears, it means that there is only fuel left for 10
more minutes. The count-do n of the remaining heating time can be seen in the
information display ¸ ( ig. K). No
¼ you remove the fuel tank and refill it outside the living room (Section B) or
¼ you push the button extension
heating time
ill e tend to 60 minutes.
The heater will automatically switch back to its lowest position. In the display
the number 60
you will hear an alarm signal every two minutes, warning you to refill the
removable tank. If you do not react, the heater will extinguish by itself. The
heater will also sound a warning signal, when it switches off. The fuel
indicator
ill blink,
display. You can stop this by pressing the
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L
THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, the heater shuts off
automatically. When this occurs, e -1 1 is displayed and the VENT indicator
blinking (fig. L). After improving the ventilation of the room (e.g. by opening a
door or window a little more), the heater can be ignited by pushing the
¹ again.
4
10
. If desired, you can switch the heater on again by pressing
hen the room temperature has dropped
ill maintain the set temperature by
you have t o options:
. By pushing this button, the remaining
ill appear,
hich
ill decline to 10. At the arrival of 10,
hile four lines (--:--) are blinking in the information
ill then appear
and holding
will appear on the
and holding it down for more
key. The SAVE indicator light
button ¹ once more.
I: When the
appears, the childproof
lock has been activated.
ill
J: When the SAVE light
lights up, the heater will
automatically switch on
or off in order to remain
within a specified tem-
perature range.
K: When the FUEL
indicator has appeard,
the information display
will show the number of
minutes of fuel left in
the tank.
is
L: A blinking VENT
indicator is a sign
button
that you need extra
ventilation.
Fuel filter
mark

Publicidad

loading