6. Wiring.

WARNING: Turn off circuit breakers to current fixture from
breaker panel and be sure switch is turned to the OFF
position.
CAUTION: Be sure outlet box is properly grounded and that a
ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local Codes
or Ordinances and the National Electrical Code. If you are
unfamiliar with electrical wiring or if the house/building wires
are different colors than those referred to in the instructions
below, please use a qualified electrician.
Note: Excess lead wire length from the fan can be cut to the
desired length and then stripped.
WARNING: If using this fan in a WET location, this fan
must be connected to a supply circuit that is protected by
a Ground Fault Circuit Interrupter (GFCI) to reduce the risk
of personal injury, electrical shock or death.
When fan is secured in place on the hanging bracket,
electrical wiring can be made as follows:
Connect BLACK and BLUE wire from fan to BLACK wire
from ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from ceiling
with wire connector provided.
Connect all GROUND (GREEN) wires together from fan to
BARE/GREEN wire from ceiling with wire connector
provided.
Since this fan does not come with a light kit, you will need
to cap off the BLUE wire with a wire connector (as shown
with arrow in diagram).
[Note: If you elect to purchase a light kit for the fan, the
BLUE wire from the fan must be connected to the BLACK
wire from the ceiling instead.]

7. Canopy Assembly.

Remove 2 screws on underside of hanging
bracket.
Lift canopy to hanging bracket. Align holes in
canopy with holes in hanging bracket. While
holding canopy in place, slide anti-sway adapter
up to canopy. Align holes in anti-sway adapter
with holes in bottom of canopy and then re-insert
the screws that were previously removed. Tighten
both screws securely.
Slide canopy cover up to anti-sway adapter,
aligning rounded part of slotted holes in canopy
cover with screw heads in bottom of anti-sway
adapter. Turn canopy cover to the right (clockwise)
until it stops.
white supply wire
black supply wire
from ceiling
black
white
white
black
blue
from fan
* Wrap each wire connector separately with electrical tape
as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately). Note: Only remote controls
approved for WET locations can be used with this
fan.
canopy
anti-sway
adapter
page 6
ground
(green or bare)
wire
connector
ground
(green
or bare)
*
hanging bracket
screw
canopy cover

Publicidad

Capítulos

Tabla de contenido
loading