Protection and Safety
Description
Insulation
Insulation
Insulation
Leakage current
Input fuse
Output fuse
Minimum output voltage of operation
(Battery Detector)
Reverse output polarity
Thermal protection of semiconductors
(Temperature of Thermal Alarm)
Safety Requirements (Rules)
EMC Requirements (Rules)
External LED Indicator
Connector 4 poles
Pin
1
Red LED anode
2
Not used
3
Common cathode LED
4
Green LED anode
Connector – Diagram connection
4
2
D01236-04
Battery charger UBC
Symbol
Use
3
1
Test Condition
-
Mains to Battery side
-
Mains side to Earth
-
Battery side to Earth
I
Supplied equipment
L
F1
Inside the equipment
F2
Inside the equipment
-
Equipment turn on
-
At the connection to the
Battery
-
Ta=55°C
-
EN60335-1, EN60335-2-29
-
EN55014-1, EN61000-3-3
EN55014-2, EN61000-4-2
EN61000-4-4, EN61000-4-5
EN61000-4-6, EN61000-4-11
INSIDE
2
1
3
4
English
Value and/or
Range
1250
500
500
< 3
7 (delayed)
40
1,3
Protection
provided by
fuse F2
100
-
-
OUTSIDE
LR
LV
Unit
V
AC
V
DC
V
DC
mA
A
A
V/cell
-
°C
-
-
13