Daikin EWAD~C-SS Manual De Instrucciones página 9

Ocultar thumbs Ver también para EWAD~C-SS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
This manual is an important supporting document for qualified personnel but it is not intended to replace such personnel.
Thank you for purchasing this chiller
READ
THIS
MANUAL
INSTALLING AND STARTING UP THE UNIT.
IMPROPER
INSTALLATION
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE
OR OTHER DAMAGE TO THE EQUIPMENT OR
INJURE TO PEOPLE.
THE
UNIT
MUST
PROFESSIONAL OPERATOR/TECHNICIAN
UNIT STARTUP HAS TO BE PERFORMED BY
AUTHORIZED AND TRAINED PROFESSIONAL
ALL
ACTIVITIES
ACCORDING TO LOCAL LAWS AND REGULATION.
UNIT
INSTALLATION
ABOSOLUTELY FORBIDDEN IF ALL INSTRUCTION
CONTAINED IN THIS MANUAL ARE NOT CLEAR.
IF
CASE
OF
MANUFACTURER REPRESENTATIVE FOR ADVICE
AND INFORMATION.
Description
The unit you bought is an "air cooled chiller", a machine aimed
to cool water (or water-glycol mixture) within the limits
described in the following. The unit operazion is based on
vapour compression, condensation and evaporation according
to reverse Carnot cycle.The main components are:
-
Screw compressor to rise the refrigerant vapour pressure
from evaporation pressure to condensation pressure
-
Evaporator, where the low pressure liquid reqrigerant
evaporates so cooling the water
-
Condenser, where high pressure vapour condensate
rejecting heat removed from the chilled water in the
atmosphere thanks to an air cooled heat exchanger.
-
Expansion valve allowing to reduced the pressure of
condensed
liquid
evaporation pressure
General Information
All units are delivered with wiring diagrams, certified
drawings, nameplate; and DOC (Declaration Of
Conformity); these documents show all technical data
for the unit you have bought and they MUST BE
CONSIDERED ESSENTIAL DOCUMENTS OF THIS
MANUAL
Label Identification
1 – Non flammable gas symbol
2 – Gas type
3 – Unit nameplate data
4 – Manufacturer's logo
5 – Water circuit filling warning
ENGLISH - ORIGINAL INSTRUCTIONS
CAREFULLY
COULD
RESULT
BE
INSTALLED
HAVE
TO
BE
PERFORMED
AND
START
DOUBT
CONTACT
from
coinsensation
pressue
Figure 1 - Description of the labels applied to the electrical panel
(The electrical panel can be of two different heights)
In case of any discrepancy between this manual and the
equipment's documents please refer to on board documents.
BEFORE
In case of any doubt contact the manufacturer representative..
IN
The purpose of this manual is to allow the installer and the
qualified operator to ensure proper installation, commissioning
and maintenance of the unit, without any risk to people,
animals and/or objects.
BY
A
Receiving the unit
The unit must be inspected for any possible damage
immediately upon reaching final place of installation. All
components described in the delivery note must be inspected
and checked.
UP
IS
Should the unit be damaged, do not remove the damaged
material
transportation company and request they inspect the unit..
THE
Immediately
representative, a set of photographs are helpful in recognizing
responsibility
Damage must not be repaired before the inspection of the
transportation company representative.
Before installing the unit, check that the model and power
supply voltage shown on the nameplate are correct.
Responsibility for any damage after acceptance of the unit
cannot be attributed to the manufacturer.
Operating limits
Storing
Environmental conditions must be within the following limits:
Minimum ambient temperature
Maximum ambient temperature
Maximum R.H.
Storing below the minimum temperature may cause damage to
components. Storing above the maximum temperature causes
to
opening of safety valves. Storing in condensing atmosphere
may damage electronic components.
Operation
Operation is allowed within the limits mentioned in Figure 2.
The unit must be operated with an evaporator water flow rate
between 50% and 140% of nominal flow rate (at standard
operating conditions).
Operation out of the mentioned limits may damage the unit.
In case of doubts contact manufacturer representative.
6 – Electrical hazard symbol
7 – Hazardous Voltage warning
8 – Cable tightening warning
9 – Lifting instructions
10 - Emergency stop
and
immediately
report
report
the
damage
:
:
:
D-EIMAC00604-14EU - 9/196
the
damage
to
the
to
the
manufacturer
-20°C
57°C
95% not condensing

Publicidad

Tabla de contenido
loading

Tabla de contenido