Dynapac SD2550C Manejo Y Mantenimiento página 255

Terminadora de firmes
Ocultar thumbs Ver también para SD2550C:
Tabla de contenido

Publicidad

Fault
SPN
FMI
Code
3911
5848
9
3912
5853
10
3917
104
18
3931
1109
0
3932
5851
16
3933
5851
18
3934
5851
2
3935
5848
13
3936
5848
12
3937
5848
10
3988
3265
9
4143
5741
3
4144
5741
4
4145
3255
9
4151
5742
9
Diesel Engine Failure-Codes chart
SPN
Lamp
Description
Aftertreatment 1
Amber
SCR Intermediate
NH3
Aftertreatment 1
SCR Intermediate
Amber
NH3 Gas Sensor
Heater
Preliminary FMI
Engine
Turbocharger
Amber
Lube Oil
Pressure 1
Engine Protection
Red
System Approach-
ing Shutdown
Aftertreatment 1
SCR Intermediate
Amber
NH3 Gas Sensor
Power In Range
Aftertreatment 1
SCR Intermediate
Amber
NH3 Gas Sensor
Power In Range
Aftertreatment 1
SCR Intermediate
Amber
NH3 Gas Sensor
Power In Range
Aftertreatment 1
Amber
SCR Intermediate
NH3
Aftertreatment 1
Amber
SCR Intermediate
NH3
Aftertreatment 1
Amber
SCR Intermediate
NH3
Aftertreatment 2
Amber
Outlet NOx
Amber
Amber
Aftertreatment 2
Amber
Intake NOx
Amber
Cumins Description
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Abnormal update rate
Aftertreatment 1 Outlet NH3 Gas Sensor Heater - Abnormal rate of
change
Engine Turbocharger Lube Oil Pressure - Data Valid But Below Nor-
mal Operating Range - Moderately Severe Level
Engine Protection System
Approaching Shutdown - Data valid but above normal operational
range
- Most
Aftertreatment 1 SCR Intermediate
NH3 Gas Sensor Power Supply - Data Valid But Above Normal
Operating Range – Most Severe
Level
Aftertreatment 1 SCR Intermediate
NH3 Gas Sensor Power Supply - Data Valid But Below Normal
Operating Range – Most Severe
Level
Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply -
Data erratic, intermittent or incorrect
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Out of Calibration
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Bad intelligent device or component
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Abnormal rate of change
Aftertreatment 2 Outlet NOx -
Abnormal Update Rate
Aftertreatment 1 Outlet Soot Sensor
- Voltage Above Normal, or Shorted to High Source
Aftertreatment 1 Outlet Soot Sensor
- Voltage below normal, or shorted to low source
Aftertreatment 2 Intake Nox Sensor -
Abnormal update rate
Aftertreatment Diesel Particulate
Filter Temperature Sensor Module - Abnormal update rate
D 22 83

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sd2550cs894895

Tabla de contenido