C. Installation instruction
Note:
1. This heat pump unit can be installed at veranda, hallway or other place where is easy to install and
stable. The air inlet & outlet are at the top side, main unit should not be placed at an open air. Avoid the
rain or debris to enter the vents. The air inlet and outlet can connect the
2. When install as Fig.1, only connect the air inlet or outlet, the unit should be installed at a place of
ventilation, and the side connected with water pipes should has enough space. Then, if the unit is
installed besides the room, it can be connected the air outlet duct to the room for exchange fresh air
and cooling function; If the unit is installed in the room, it can be pulled out room's air for ventilation
function.
3. If install as Fig. 2, the unit can be installed by the middle of the wall, and connect the air inlet and outlet
pipe for air exchange. The distance of the unit and wall or other obstacle should not be too short. Keep
a certain distance.
4. If install as Fig. 3, the unit is installed outside the room, the
air inlet and outlet is connected indoor for air exchange
(and cooling). In this way, the indoor air inlet and outlet
should have a distance ≥2m to avoid mix air.
5. Because the air outlet comes with cooling air, the surface
of the pipe may have condensation water, it's necessary to
insulate the indoor outlet pipe to prevent water leakage.
6. Heat pump water heater unit must be placed upright, and
installed on a solid place where can be able to withstand
the weight over 360kgs. Supporting surface should be
evenness (obliquity less than 2°)
7. When install the unit, there should has some measures of
sound insulation and shockproof in order not to affect
neighbors.
CLOCK
ON/OFF
TIMER
MODE
≥600mm
(Fig.1)
≥600mm
(Fig.2)
3
150mm air duct. As below,
φ
CLOCK
ON/OFF
TIMER
MODE
≥500mm
≥600mm
(Fig. 3)
CLOCK
ON/OFF
TIMER
MODE
V.3