E. Maintenance and service
Heat Pump main unit disassembly
If want to check and maintain the top main parts of the unit, should disassembly the cover of the unit,
follow the below steps (Fig.5, 6) to process.
1. Move up the control panel and its components-1(including control panel、decorative panel,
decorative aluminum profile、decorative strip) vertically 15-20mm, then pull it out horizontally to
separate hook A-2 from hook A-3 until exposed butt splice connector;
2. Disconnect control panel with butt splice connector;
3. Remove all screws-5 from the bottom of the top cover.
4. Release the power line from the top cover of fixed terminal, to prevent the power line stuck when
move up the top cover.
5. Finally, remove the block objects (e.g. air ducts etc.) from the air inlet /outlet, holding both sides of
the top covers and move it up.